The document file for Real mode ADI driver(ADIHDG.COM / Ver 3.0)
========================================================================
The file ADIHDG.COM is a memory resident program that allows a
Hitachi tablet listed below to interface with AutoDesk programs such as
AutoCAD, AutoSketch, AutoShade, or any other AutoDesk application software
that can use a real-mode ADI digitizer driver.
HDG-1111C
HDG-1212D
HDG-1217D
HDG-1515D
HDG-1717D
HDG-2222/2222S/2222T
HDG-2436/2436S/2436T
HDG-3648/3648S/3648T
HDG-4460/4460S/4460T
HDG-1212E
To install the ADIHDG driver, you need to set the functions of Tablet
by DIP swiches or Menu sheets.
1. For HDG-1111C with Pen/4-B cursor
DSW1 - 1, 3 and 4 ; ON
DSW2 - 3 and 5 ; ON
DSW3 - All ; OFF
If 12-B cursor is used, DSW3-4 must be ON.
(Note) The HDG-1111C will be set as;
0.025mm, REMOTE mode, Lower-left origin,
9600bps, 7-data, Even parity, 1-stop
ASCII format(Hitachi)
2. For HDG-1212D, 1515D, 1717D and 1217D
DSW1 - all ; OFF
(Note) The D-series tablet will be set as;
0.025mm, REMOTE mode, Lower-left origin,
9600bps, 7-data, Even parity, 1-stop
ASCII format(Hitachi)
3. For HDG-2222 - HDG-4460 with DP004 I/F board
MODE/RATE(DIP switch) - all ; OFF
BAUDRATE(DIP switch) - 8 ; ON
Jumper pin on the board - 1S and ASYNC(2) ; ON
(Note) The large tablets with I/F board(DP004) will be set as;
0.025mm, REMOTE mode, Lower-left origin,
9600bps, 7-data, Even parity, 1-stop
ASCII fotmat(Hitachi)
4. For HDG-2222S - HDG-4460S with DP401 I/F board
DSW1 - all ; OFF
DSW2 - 2 and 4 ; ON
DSW3 - 1 and 2 ; ON
(Note) The large tablets with I/F board(DP401) will be set as;
0.025mm, REMOTE mode, Lower-left origin,
9600bps, 7-data, Even parity, 1-stop
ASCII fotmat(Hitachi)
5. For HDG-2222T - HDG-4460T
HITACHI-1 Default
(Note) The T-series large tablet will be set as;
0.001", RUN mode, Lower-left origin,
9600bps, 7-data, Even parity, 1-stop,
ASCII format(Hitachi)
6. For HDG-1212E
HITACHI Default
(Note) The HDG-1212E will be set as;
0.025mm, REMOTE mode, Lower-left origin,
9600bps, 7-data, Even parity, 1-stop
ASCII format(Hitachi)
You can type the file name followed by command line arguments that tell the
driver the tablet type and configuration, or modify AUTOEXEC.BAT file so the
driver is loaded whenever you start your PC.:
ADIHDG [/n] [/M#####] [/C#] [/P#] [/U]
[/n] is a one-digit number that specifies which serial port is being used
to communicate with the tablet.
If no port argument is given, the ADIHDG driver will be installed
on COM1.
/1 designates COM1 (Default)
/2 designates COM2
[/M#####] The second argument selects the tablet model being used:
/M1111C selects the HDG-1111C
/M1212E selects the HDG-1212E (Default)
/M1212D selects the HDG-1212D
/M1515D selects the HDG-1515D
/M1717D selects the HDG-1717D
/M1217D selects the HDG-1217D
/M2222S selects the HDG-2222/2222S
/M2436S selects the HDG-2436/2436S
/M3648S selects the HDG-3648/3648S
/M4460S selects the HDG-4460/4460S
/M2222T selects the HDG-2222T
/M2436T selects the HDG-2436T
/M3648T selects the HDG-3648T
/M4460T selects the HDG-4460T
If no /M##### is given, the driver assumes a default HDG-1212E.
[/C#] is a designator for the type of cursor or stylus being used
by the driver:
The default cursor type is the /C4 (4-button cursor).
/CP selects a PEN or stylus
/C4 selects a 4-button cursor (Default)
/C12 selects a 12-button cursor
/C16 selects a 16-button cursor for HDG-1212E and Large
tablet only.
[Pointing Device Button Definitions]
The following lists the digitizer button functions that are executed when
using the ADIHDG driver with Standard configuration(i.e., unmodified acad.mnu
file) of AutoCAD.
This button mapping may be modified by editing the acad.mnu file.
For instructions to modify the acad.mnu file, refer to the AutoCAD "Reference
Manual" supplied with your AutoCAD.
Button AutoCAD Function
Stylus Pen Tip switch Pick
Barrel Switch Carriage Return
4-button cursor Yellow Pick
White Carriage Return
Blue Displays Pull-down Menu #1(Tools)
Green Cancel
12-button cursor 1 Pick
2 Carriage Return
3 Displays Pull-down Menu #1(Tools)
4 Cancel
5 Snap On/Off
6 Ortho On/Off
7 Grid On/Off
8 Coordinate display On/Off
9 Isoplane Top/Right/Left
* Tablet On/Off
0 Not defined
# Not defined
16-button cursor 1 Pick
for HDG-1212E 2 Carriage Return
3 Displays Pull-down Menu #1(Tools)
4 Cancel
5 Snap On/Off
6 Ortho On/Off
7 Grid On/Off
8 Coordinate display On/Off
9 Isoplane Top/Right/Left
A Tablet On/Off
0 Not defined
B,C,D,E and F Not defined
16-button cursor 1 Pick
for Large tablet 2 Carriage Return
3 Displays Pull-down Menu #1(Tools)
4 Cancel
5 Snap On/Off
6 Ortho On/Off
7 Grid On/Off
8 Coordinate display On/Off
9 Isoplane Top/Right/Left
* Tablet On/Off
0 Not defined
#,A,B,C and D Not defined
[P#] This argument allows you to assign the same function button
as HICOMSCAN driver under AutoCAD if [P0] is used.(The pick
button will be "0" button of 12-B cursor.)
This argument is valid only when 12-B cursor[/C12] or 16-B
cursor[/C16] is used.
If no [P#] is given, the pick button will be "1".
/P1 -- The pick button will be the "1" button. (Default)
(See the above function table)
/P0 -- The pick button will be the "0" button.
(Same function as HICOMSCAN driver)
(12-button cursor)
1 Carriage Return
2 Displays Pull-down Menu #1(Tools)
3 Cancel
4 Snap On/Off
5 Ortho On/Off
6 Grid On/Off
7 Coordinate display On/Off
8 Isoplane Top/Right/Left
9 Tablet Off
* Not defined
0 Pick
# Not defined
[/U] This argument allows you to remove the driver from memory.
For example, if you want to install ADIHDG.COM with the HDG-1217D on COM1 and
12-button cursor, follows the step listed below.
- Insert "Hitachi drivers" diskette into A:.
- Type A: and press Enter key.
- Type as follows at DOS prompt(A:>).
A:>ADIHDG /M1217D /C12
After you install the ADIHDG driver, you are ready to start AutoCAD or
other AutoDeask's software products that support Real mode ADI digitizer.
And you may need to run the CONFIGURE program within AutoDesk's software
to select "Real mode ADI digitizer" as input device. To configure the Real
mode ADI driver, select "AutoDesk Device Interface" in the digitizer
configuration menu.
(Trademark)
ADI, AutoCAD and AutoShade are trademarks of Autodesk,Inc.